Maketning tavsifi
Maketda germaniyli, kam quvvatli, past chastotali MP 42 tranzistor ishlatiladi. Uning parametrlaridan ishchi kuchlanishi U=(30..50)V, kollektor sig‘imi SK=30 pF, maksimal quvvati RMAX=200 mVt.
Sxemaning boshqa elementlari parametrlari qo‘yidagicha:
R1=1 kOm, R2=11 kOm, R3=5.1 kOm, R4=3.6 kOm, R5=3.6 kOm, R6=47 kOm, R7=20 Om, R8=510 Om, R9=3.6 kOm, R10=10kOm, S1=S2=S3=20 mkF.
Ishni bajarish tartibi:
Maketni elektr tarmog‘iga ulang. Standart signallar generatori (SSG) va kirish qarshiligi yuqori bo‘lgan o‘zgaruvchan kuchlanishlarni o‘lchaydigan asbob (millivoltmetr) ni ishga tayyorlang.
3. UB ulangan sxemani o‘rganish
3.1. Tranzistor bazasi umumiy ulangan kuchaytirgich sxemasini yig‘ing. Buning uchun ulagichlarni jadvalda ko‘rsatilgan holatlarga keltiring. U12-15 ulagichning 15 holatda sxemaga R10=10 kOm rezistor yuklama sifatida ulanadi RYu=R10=10 kOm
Ish bandi
|
Ulagich xolati
|
Nazorat nuqtasi
|
Sxemaning kirishi
|
U1-2
|
U3-4
|
U5-6
|
U7-8
|
U12-15
|
3.1-3.3
|
2
|
4
|
5
|
7
|
15
|
3
|
kirish 1
|
1.2-1.9 bandlarga muvofiq o‘lchashlarni takrorlang.
Maket yuzasining yuqori qismida joylashgan nazorat nuqtalarga voltmetr va ossillograf ulang.
N3 nazorat nuqta potensialini kirishi ochiq ossilograf yoki o‘zgarmas kuchlanishni o‘lchaydigan boshqa asbob yordamida kuzatib G1 taminot manbaining kuchlanishini 6V ga keltiring.
O‘zgarmas kuchlanishni o‘lchaydigan asbobni N4, N5, N2 nazorat nuqtalarga ulab tranzistorning sokinlik xolati parametrlarini aniqlang. Nazorat nuqtalarning o‘lchangan potensiallari va R4 = 3,6 kOm, R5=3,6 kOm rezistorlar qiymatlarini xisobga olib kollektor, emitter va baza sokinlik toklarini toping.
Ish bandi
|
Ulagich xolati
|
Nazorat nuqtasi
|
Sxemaning kirishi
|
U1-2
|
U3-4
|
U5-6
|
U7-8
|
U12-15
|
3.5
|
2
|
4
|
5
|
7
|
15
|
2/4/5
|
kirish 1
|
3.6. Sxemaning kuchlanish bo‘yicha kuchaytirish koeffitsiyenti KU ni toping. Buning uchun sinusoidal generatordan 2 kGts chastotali 30 mV kuchlanishli signalni sxemaning “kirish N2” nuqtasiga uzating. Kirish kuchlanishi nol potensialli shina va N2 nazorat nuqta orasida o‘lchanadi. Chiqish kuchlanishini o‘lchashda voltmetrni N7 nazorat nuqtaga ulash tavsiya etiladi.
Ish bandi
|
Ulagich xolati
|
Nazorat nuqtasi
|
Sxemaning kirishi
|
U1-2
|
U3-4
|
U5-6
|
U7-8
|
U12-15
|
3.5-3.8
|
2
|
4
|
5
|
7
|
14
|
7
|
kirish 1
|
3.7. Kuchlanish bo‘yicha kuchaytirish koeffitsiyentining chastotaviy xarakteristikasi KU(f) ni o‘lchang. Buning uchun kirish kuchlanishi amplitudasini o‘zgarishsiz (taxminan 30 mV) saqlab, uning chastotasini o‘zgartiring va chiqish kuchlanishini N7 nazorat nuqtada o‘lchang. O‘lchashlarni test signallarining 10 Gts, 100 Gts, 1 kGts, 10 kGts, 100 kGts, 1 mGts qiymatlarda bajarish tavsiya etiladi.
3.8. 2 kGts chastotada sxemaning amplituda xarakteristikasi UChIQ=f(UKIR) ni o‘lchang. Bunda kirish signali kuchlanishini 10..300 mV oraliqda o‘zgartirish tavsiya etiladi.
3.9. Kuchaytirgich bosqichi dinamik diapazoni yuqori chegarasini aniqlang. Buning uchun chiqish kuchlanishi ossillogrammasini kuzata borib kirish signalining qaysi qiymatida nochiziqli buzilishlar paydo bo‘lishini aniqlang.
3.10. Kirish kuchlanishi 30 mV, chastotasi 2 kGts bo‘lganda, kuchaytirgich kaskadi chiqishiga R7=20 Om, R8=510 Om, R9=3,6 kOm, R10=10 kOm rezistorlarni U12-15 ulagich yordamida navbatma-navbat ulab, uning yuklama xarakteristikasi KU(RYu) ni o‘lchang.
Ish bandi
|
Ulagich xolati
|
Nazorat nuqtasi
|
Sxemaning kirishi
|
U1-2
|
U3-4
|
U5-6
|
U7-8
|
U12-15
|
3.9
|
2
|
4
|
5
|
7
|
12..15
|
7
|
kirish 1
|
3.11. Ta’minot manbaining kuchlanishi 9 va 12V bo‘lganda 4,5,7,8,9 bandlarga muvofiq o‘lchashlarni takrorlang.
Do'stlaringiz bilan baham: |