A
Common combustibles
Water, soda acid (a dry powder or liquid chemical)
B
Liquids
CO2, halon*, soda acid
C
Electrical
CO2, halon*
D
Metal
Dry powder
* Halon or an EPA-approved halon substitute 
Water cannot be used on Class B fires because it splashes the burning liq-
uids and such liquids usually float on water. Water cannot be used on Class 
C fires because of the potential for electrocution. Oxygen suppression 
cannot be used on metal fires because burning metal produces its own 
oxygen.


420
Chapter 10 

Physical Security Requirements
Fire Detection Systems
To properly protect a facility from fire requires installing an automated detection and 
suppression system. There are many types of fire detection systems. 
Fixed-temperature 
detection
systems trigger suppression when a specific temperature is reached. The trigger 
is usually a metal or plastic component that is in the sprinkler head and melts at a specific 
temperature. There is also a version with a small glass vial containing chemicals that vapor-
ize to overpressurize the container at a specific temperature. 
Rate-of-rise detection
systems 
trigger suppression when the speed at which the temperature changes reaches a specific 
level. 
Flame-actuated
systems trigger suppression based on the infrared energy of flames. 
Smoke-actuated
systems use photoelectric or radioactive ionization sensors as triggers. 
Incipient smoke detection systems, also known as aspirating sensors, are able to detect the 
chemicals typically associated with the very early stages of combustion before a fire is oth-
erwise detectible via other means.
Most fire-detection systems can be linked to fire response service notification mecha-
nisms. When suppression is triggered, such linked systems will contact the local fire 
response team and request aid using an automated message or alarm.
To be effective, fire detectors need to be placed strategically. Don’t forget to place them 
inside dropped ceilings and raised floors, in server rooms, in private offices and public 
areas, in HVAC vents, in elevator shafts, in the basement, and so on.
As for suppression mechanisms used, they can be based on water or on a fire suppression 
gas system. Water is common in human-friendly environments, whereas gaseous systems 
are more appropriate for computer rooms where personnel typically do not reside.

Download 19,3 Mb.

Do'stlaringiz bilan baham:
1   ...   392   393   394   395   396   397   398   399   ...   881




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish